| Medicus HF | Medicus HF plan 20 | |||
| Stand: | Quadruple revolving nosepiece | √ | √ | ||
| Method of contrast: | Brightfield | √ | √ | ||
| phase contrast | |||||
| Transmitted light brightfield and LED fluorescence illuminator with filterset G in combination with the fluorescence dye Mykoval | |||||
| Tube: | Binocular, 30° | √ | √ | ||
| Eyepieces: | Widefield 10x/18 | √ | |||
| Widefield 10x/20 | √ | ||||
| Objectives: | AC 4/0,10; AC 10/0,25; AC 40/0,65; AC 100/1,25 (Oil) | √ | |||
| Achro 10/0,25, Plan Ph 40/0,65, Achro 100/1,25 (Oil) | |||||
| Plan 4x/ 0.10; Plan 10/0,25; Plan 40/0,65; Plan 100/1,25 (Oil) | √ | ||||
| Plan 4x/ 0.10, Plan 10/0,25, Plan Ph 40/0,65, Plan 100/1,25 (Oil) | |||||
| Magnification: | 40 - 1000times or more | √ | √ | ||
| Object stage: | Mechanical stage 130x130mm | √ | √ | ||
| Condenser: | NA 1,25/0,6 with aperture diaphragm and filterholder | √ | √ | ||
| Brightfield condenser NA 0.9 with aperture diaphragm and filterholder | |||||
| Illumination: | 6V / 20W halogen, continuous regulation | √ | √ | ||
| Accessories: | Dust cover, spare lamp, spare fuse, immersion oil, centering key, mains cable | √ | √ | ||
| Mains cable, 1 spare bulb, 2 spare fuses, instruction for use, dust cover, fluorescence dye Mykoval, dust cover | |||||
| Order number: | 008.0095.0 | 008.0342.0 | |||

| Medicus PH Achro PL | Medicus PH PLAN | |||
| Stand: | Quadruple revolving nosepiece | √ | √ | ||
| Method of contrast: | Brightfield | √ | √ | ||
| phase contrast | √ | √ | |||
| Transmitted light brightfield and LED fluorescence illuminator with filterset G in combination with the fluorescence dye Mykoval | |||||
| Tube: | Binocular, 30° | √ | √ | ||
| Eyepieces: | Widefield 10x/18 | √ | |||
| Widefield 10x/20 | √ | ||||
| Objectives: | AC 4/0,10; AC 10/0,25; AC 40/0,65; AC 100/1,25 (Oil) | ||||
| Achro 10/0,25, Plan Ph 40/0,65, Achro 100/1,25 (Oil) | √ | ||||
| Plan 4x/ 0.10; Plan 10/0,25; Plan 40/0,65; Plan 100/1,25 (Oil) | |||||
| Plan 4x/ 0.10, Plan 10/0,25, Plan Ph 40/0,65, Plan 100/1,25 (Oil) | √ | ||||
| Magnification: | 40 - 1000times or more | √ | √ | ||
| Object stage: | Mechanical stage 130x130mm | √ | √ | ||
| Condenser: | NA 1,25/0,6 with aperture diaphragm and filterholder | √ | √ | ||
| Brightfield condenser NA 0.9 with aperture diaphragm and filterholder | |||||
| Illumination: | 6V / 20W halogen, continuous regulation | √ | √ | ||
| Accessories: | Dust cover, spare lamp, spare fuse, immersion oil, centering key, mains cable | √ | √ | ||
| Mains cable, 1 spare bulb, 2 spare fuses, instruction for use, dust cover, fluorescence dye Mykoval, dust cover | |||||
| Order number: | 008.0344.0 | 008.0345.0 | |||

| Medicus LED AFL ACHRO | Medicus PHASE LED AFL | |||
| Stand: | Quadruple revolving nosepiece | √ | √ | ||
| Method of contrast: | Brightfield | √ | √ | ||
| phase contrast | √ | √ | |||
| Transmitted light brightfield and LED fluorescence illuminator with filterset G in combination with the fluorescence dye Mykoval | √ | √ | |||
| Tube: | Binocular, 30° | √ | √ | ||
| Eyepieces: | Widefield 10x/18 | √ | √ | ||
| Widefield 10x/20 | |||||
| Objectives: | AC 4/0,10; AC 10/0,25; AC 40/0,65; AC 100/1,25 (Oil) | √ | |||
| Achro 10/0,25, Plan Ph 40/0,65, Achro 100/1,25 (Oil) | √ | ||||
| Plan 4x/ 0.10; Plan 10/0,25; Plan 40/0,65; Plan 100/1,25 (Oil) | |||||
| Plan 4x/ 0.10, Plan 10/0,25, Plan Ph 40/0,65, Plan 100/1,25 (Oil) | |||||
| Magnification: | 40 - 1000times or more | √ | √ | ||
| Object stage: | Mechanical stage 130x130mm | √ | √ | ||
| Condenser: | NA 1,25/0,6 with aperture diaphragm and filterholder | ||||
| Brightfield condenser NA 0.9 with aperture diaphragm and filterholder | √ | √ | |||
| Illumination: | 6V / 20W halogen, continuous regulation | √ | √ | ||
| Accessories: | Dust cover, spare lamp, spare fuse, immersion oil, centering key, mains cable | √ | |||
| Mains cable, 1 spare bulb, 2 spare fuses, instruction for use, dust cover, fluorescence dye Mykoval, dust cover | √ | √ | |||
| Order number: | 008.0364.0 | 008.0378.0 | |||